**To get information about a detector model** The following ``describe-detector-model`` example displays details for the specified detector model. Because the ``version`` parameter is not specified, information about the latest version is returned. :: aws iotevents describe-detector-model \ --detector-model-name motorDetectorModel Output:: { "detectorModel": { "detectorModelConfiguration": { "status": "ACTIVE", "lastUpdateTime": 1560796816.077, "roleArn": "arn:aws:iam::123456789012:role/IoTEventsRole", "creationTime": 1560796816.077, "detectorModelArn": "arn:aws:iotevents:us-west-2:123456789012:detectorModel/motorDetectorModel", "key": "motorid", "detectorModelName": "motorDetectorModel", "detectorModelVersion": "1" }, "detectorModelDefinition": { "states": [ { "onInput": { "transitionEvents": [ { "eventName": "Overpressurized", "actions": [ { "setVariable": { "variableName": "pressureThresholdBreached", "value": "$variable.pressureThresholdBreached + 3" } } ], "condition": "$input.PressureInput.sensorData.pressure > 70", "nextState": "Dangerous" } ], "events": [] }, "stateName": "Normal", "onEnter": { "events": [ { "eventName": "init", "actions": [ { "setVariable": { "variableName": "pressureThresholdBreached", "value": "0" } } ], "condition": "true" } ] }, "onExit": { "events": [] } }, { "onInput": { "transitionEvents": [ { "eventName": "BackToNormal", "actions": [], "condition": "$input.PressureInput.sensorData.pressure <= 70 && $variable.pressureThresholdBreached <= 1", "nextState": "Normal" } ], "events": [ { "eventName": "Overpressurized", "actions": [ { "setVariable": { "variableName": "pressureThresholdBreached", "value": "3" } } ], "condition": "$input.PressureInput.sensorData.pressure > 70" }, { "eventName": "Pressure Okay", "actions": [ { "setVariable": { "variableName": "pressureThresholdBreached", "value": "$variable.pressureThresholdBreached - 1" } } ], "condition": "$input.PressureInput.sensorData.pressure <= 70" } ] }, "stateName": "Dangerous", "onEnter": { "events": [ { "eventName": "Pressure Threshold Breached", "actions": [ { "sns": { "targetArn": "arn:aws:sns:us-east-1:123456789012:underPressureAction" } } ], "condition": "$variable.pressureThresholdBreached > 1" } ] }, "onExit": { "events": [ { "eventName": "Normal Pressure Restored", "actions": [ { "sns": { "targetArn": "arn:aws:sns:us-east-1:123456789012:pressureClearedAction" } } ], "condition": "true" } ] } } ], "initialStateName": "Normal" } } } For more information, see `DescribeDetectorModel <https://docs.aws.amazon.com/iotevents/latest/apireference/API_DescribeDetectorModel>`__ in the *AWS IoT Events API Reference*.
Name | Type | Size | Permission | Actions |
---|---|---|---|---|
batch-put-message.rst | File | 1.12 KB | 0644 |
|
batch-update-detector.rst | File | 1.16 KB | 0644 |
|
create-detector-model.rst | File | 5.99 KB | 0644 |
|
create-input.rst | File | 1.02 KB | 0644 |
|
delete-detector-model.rst | File | 482 B | 0644 |
|
delete-input.rst | File | 356 B | 0644 |
|
describe-detector-model.rst | File | 6.58 KB | 0644 |
|
describe-detector.rst | File | 1.03 KB | 0644 |
|
describe-input.rst | File | 1.07 KB | 0644 |
|
describe-logging-options.rst | File | 588 B | 0644 |
|
list-detector-model-versions.rst | File | 1.03 KB | 0644 |
|
list-detector-models.rst | File | 698 B | 0644 |
|
list-detectors.rst | File | 863 B | 0644 |
|
list-inputs.rst | File | 698 B | 0644 |
|
list-tags-for-resource.rst | File | 618 B | 0644 |
|
put-logging-options.rst | File | 1.13 KB | 0644 |
|
tag-resource.rst | File | 724 B | 0644 |
|
untag-resource.rst | File | 500 B | 0644 |
|
update-detector-model.rst | File | 6.02 KB | 0644 |
|
update-input.rst | File | 1.07 KB | 0644 |
|